Fichier:Notes on heating and ventilation (1906) (14578633458).jpg

Fichier d’origine(2 050 × 3 094 pixels, taille du fichier : 509 kio, type MIME : image/jpeg)

Ce fichier et sa description proviennent de Wikimedia Commons.

Description

Description
English:

Identifier: notesonheatingve01alle (find matches)
Title: Notes on heating and ventilation
Year: 1906 (1900s)
Authors: Allen, John Robins, 1869-1920
Subjects: Heating Ventilation
Publisher: Chicago, Domestic engineering
Contributing Library: The Library of Congress
Digitizing Sponsor: The Library of Congress

View Book Page: Book Viewer
About This Book: Catalog Entry
View All Images: All Images From Book
Click here to view book online to see this illustration in context in a browseable online version of this book.

Text Appearing Before Image:
lation perature of the water. In the open tank systemthis tank is situated at the highest point of thesystem. In the closed tank system it may be lo-cated anywhere in the building. TABLE XXII.Proportion of Cast Iron Hot Water Boilers. c O T3 b4 a> ■*- C -*-> oj !2 a .2 5 T3 to 0« <j •11 3 — p3 VI- -J- C7 o <u o E C/3 C/) (/) . 300 25 1 2 8 400 30 1.3 2 8 500 40 1.6 2V2 9 750 60 2.5 2V2 9 1,000 80 3.3 3 9 1500 120 5.0 SV2 10 2.000 160 6.5 4 H 2 500 200 8.5 5or2-3y2 12 3 000 250 10.0 6 or 2-4 14 SSOO 280 11.5 6 or 2-4 16 4 000 330 13.5 6 or 2-5 18 5*000 400 16.5 7 or 2-5 26 6000 500 20 8 or 2-6 22 T^OOO 575 23 8 or 2-6 24 8 000 650 26.5 2-7 or 3-5 26 9000 750 30 2-7 or 3-5 26 lOoOO 800 33.5 2-8 or 2-6 28 IIOOO 900 36.5 2-8 or 2-6 28 Pitch.—The pitch of the pipe refers to its in-clination from the horizontal. Legs of the System.—The flow main is oftentermed the hot leg of the system and the returnmain the cold leg of the system. Notes on Heating and Ventilation 1^9
Text Appearing After Image:
Figure 47. 160 Notes on Heating and Ventilation Four systems of piping areSystems of Piping, used—the multiple circuit system, the single circuit sys-tem, the overhead system, and the single pipe sys-tem. Multiple Circuit System.—This system is theone most used and is sometimes called the standardsystem of piping. This system is shown in Fig. 47.The flow main rises from the top of the boiler toa convenient height just below the basement ceil-ing so as to allow for pitch towards the boiler ofnot less than ^ an inch in 10 feet. This main ormains is carried around the basement so as to sup-ply the risers. Too many risers should not betaken from one set of mains, as the radiators atthe end will be too much cooled. The main re-turn is parallel to the flow^ main and of thesame size. The open expansion tank is placedat least 3 feet above the last radiator andshould be connected to the nearest riser. Theconnection to the expansion tank should be at thebottom of the tank. In this system th

Note About Images

Please note that these images are extracted from scanned page images that may have been digitally enhanced for readability - coloration and appearance of these illustrations may not perfectly resemble the original work.
Date
Source

https://www.flickr.com/photos/internetarchivebookimages/14578633458/

Auteur Allen, John Robins, 1869-1920
Autorisation
(Réutilisation de ce fichier)
At the time of upload, the image license was automatically confirmed using the Flickr API. For more information see Flickr API detail.
Flickr tags
InfoField
  • bookid:notesonheatingve01alle
  • bookyear:1906
  • bookdecade:1900
  • bookcentury:1900
  • bookauthor:Allen__John_Robins__1869_1920
  • booksubject:Heating
  • booksubject:Ventilation
  • bookpublisher:Chicago__Domestic_engineering
  • bookcontributor:The_Library_of_Congress
  • booksponsor:The_Library_of_Congress
  • bookleafnumber:164
  • bookcollection:library_of_congress
  • bookcollection:americana
Flickr posted date
InfoField
28 juillet 2014



Conditions d’utilisation

Cette image est issue de la collection The Commons du site Flickr. Les organismes y partageant leur collection déclarent qu'à leur connaissance, aucune restriction de droit d'auteur ne fait obstacle à leur diffusion, pour l'une des raisons suivantes :
  1. l'œuvre est dans le domaine public car les droits d'auteur ont expiré ;
  2. l'œuvre a été rattachée au domaine public pour d'autres raisons, tel que le non respect des conditions nécessaires pour renouveler des droits d'auteur ;
  3. l'organisme est détenteur des droits d'auteur mais ne ne souhaite pas exercer son contrôle ou ;
  4. l'organisme possède des droits suffisant pour permettre à des tiers d'utiliser ces travaux sans aucune restriction.

La page https://flickr.com/commons/usage/ donne à ce sujet plus d'informations.


Merci d'ajouter des bandeaux de licence supplémentaires à cette image si des informations plus spécifiques sont disponibles à propos du statut de cette image. Consultez Commons:À propos des licences pour plus d'informations.
Cette image a été originellement postée sur Flickr par Internet Archive Book Images à l'adresse https://flickr.com/photos/126377022@N07/14578633458. Elle a été passée en revue le 8 octobre 2015 par le robot FlickreviewR, qui a confirmé qu'elle se trouvait sous licence No known copyright restrictions.

8 octobre 2015

Légendes

Ajoutez en une ligne la description de ce que représente ce fichier

Éléments décrits dans ce fichier

dépeint

image/jpeg

Historique du fichier

Cliquer sur une date et heure pour voir le fichier tel qu'il était à ce moment-là.

Date et heureVignetteDimensionsUtilisateurCommentaire
actuel8 octobre 2015 à 11:06Vignette pour la version du 8 octobre 2015 à 11:062 050 × 3 094 (509 kio)== {{int:filedesc}} == {{information |description={{en|1=<br> '''Identifier''': notesonheatingve01alle ([https://commons.wikimedia.org/w/index.php?title=Special%3ASearch&profile=default&fulltext=Search&search=insource%3A%2Fnotesonheatingve01alle%2F fin...

La page suivante utilise ce fichier :

Usage global du fichier

Les autres wikis suivants utilisent ce fichier :